MIR Spirobank II Basic spirometer
The MIR Spirobank II Basic spirometer is a portable spirometer capable of measuring most of the basic parameters of respiratory function, with accurate measurements, quick and easy to operate, and with a navigation menu with the help of icons.
The MIR Spirobank II Basic spirometer has a high-resolution display and backlight. Results are displayed instantly on the screen with a preview of the curves for data analysis and test interpretation. It works with a long-life rechargeable battery (40 hours of continuous operation). Furthermore, the MIR Spirobank II Basic spirometer has a built-in memory of 10,000 measurements. It connects to a computer and performs the exam in real time via a USB connection.
In addition, the MIR Spirobank II Basic spirometer performs an Estimated Lung Age (ELA) test to assess the benefits of smoking cessation. It is an ideal choice for family physicians, primary care physicians, pulmonologists, etc. It comes with the high functionality winspiroPRO® software (with free upgrades).
The package includes the MIR Spirobank II Basic spirometer, 60 turbines, a carrying case, and a USB cable.
Spirometry parameters: FVC, VC, IVC, PRE/POST, IC, ERV, FEV1, FEV1%, PEF, FEF 25-75, FET, EVOL, ELA
Specifications:
- Width: 55mm
- Length: 160mm
- Thickness: 25mm
- Weight: 140g (battery included)
- Rechargeable battery: Lithium-Ion 3.7V, 1100mAh
- Current capacity: 1100 mAh
- Consumption: ~20-30 mA (during the test)
- Connector: micro USB type B
- Autonomy: 40 hours
- Connectivity: USB 2.0
- Display: LCD, 160 × 80 pixels
- Mouthpieces: Ø 30 mm (1.18 inches)
- Measurement memory: 10,0000 tests
The package includes:
- Carrying case
- USB cable
- Noseclip
- PC Software
- 60 FlowMIR turbines
Compatible turbines:
Mouthpiece | Turbine Disinfection |
Turbine Calibration |
Packaging | Antiviral filter |
|
---|---|---|---|---|---|
FlowMIR Disposable Turbine |
Included Disposable |
Not required |
Not required |
60 pieces | Available Disposable |
Reusable Turbine | Required, Not included |
Required | Required | 1 unit | Required, Disposable |
Technical Specification |
Spirobank II Basic |
Spirobank II Advanced |
Spirobank II Smart |
---|---|---|---|
Type of spirometer | StandAlone + PC | StandAlone + PC, with Oximetry Option |
StandAlone + PC + App, with Oximetry Option |
Compatible turbines | flowMIR™ Disposable Turbine, Reusable Turbine Flowmeter |
flowMIR™ Disposable Turbine, Reusable Turbine Flowmeter |
flowMIR™ Disposable Turbine, Reusable Turbine Flowmeter |
Compatible softwares | Winspiro PRO, spiro Connect | MIR Spiro App, Winspiro PRO, spiro Connect |
|
External control | Real-Time test on PC screen, connect with your EHR/EMR, back-up internal memory and much more Connect to your PC via USB |
Real-Time test on PC screen, connect with your EHR/EMR, back-up internal memory, and much more Connect to your PC via USB and Bluetooth 2.0 |
Real-Time test on Tablet and PC screen, connect with your EHR/EMR, backup internal memory, and much more Connect to your PC via USB (no Bluetooth) Connect to your Tablet via Bluetooth Smart BLE 4.0 |
EHR connectivity | Via PC, integration with patient database on your EHR/EMR (in HL7, GDT) |
Via PC, integration with patient database on your EHR/EMR (in HL7, GDT) |
Via PC: integration with patient database on your EHR/EMR (in HL7, GDT) Via APP: transfer data to a remote server in HL7 standards |
Measured parameters | Spirometry: FVC, VC, IVC, PRE/POST Bronchodilator comparison Spirometry: FVC, VC, IVC, IC, ERV, FEV1, FEV1%, PEF, FEF 25-75, FET, EVOL, ELA |
Spirometry: FVC, VC, IVC, MVV, PRE-POST Bronchodilator comparison Oximetry (optional): Spot test (SpO2, BPM) Spirometry: FVC, FEV1, FEV1/FVC%, DTPEF, FEV 0.5, FEV0.5/FVC%, FEV0.75, FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FEF75-85%, FET, Vext, ELA, EVOL, FIVC, FIV1, PIF, FIV1/FIVC%, FIF25%, FIF50%, FIF75%, R50, PIF, IRV, VC, IVC, IC, ERV, FEV1/VC%, TV, VE, RR, ti, te, ti/t-tot, TV/ti, MVV Oximetry (Optional): SpO2% (min, max, average), BPM (min, max, average), Test duration, % Bradycardia Duration (<40 BPM), % Tachycardia Duration (>120 BPM), % of Time with SpO2 ≤ 90% (T90%, T89%) |
Spirometry: FVC, VC, IVC, MVV, PRE-POST Bronchodilator comparison Oximetry (optional): Spot test (SpO2, BPM) Spirometry: FVC, FEV1, FEV1/FVC%, DTPEF, FEV 0.5, FEV0.5/FVC%, FEV0.75, FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25, FEF50, FEF75, FEF25-75, FEF75-85%, FET, Vext, ELA, EVOL, FIVC, FIV1, PIF, FIV1/FIVC%, FIF25, FIF50, FIF75, R50, PIF, IRV, VC, IVC, IC, ERV, FEV1/VC%, TV, VE, RR, tI, tE, tI/t-tot, TV/tI, MVV Oximetry (Optional): SpO2% (min, max, average), BPM (min, max, average), Test duration, % Bradycardia Duration (<40 BPM), % Tachycardia Duration (>120 BPM), % of Time with SpO2 ≤ 90% (T90%, T89%) on MIR Spiro App: Spirometry: FVC, VC, PRE/POST Bronchodilator comparison Parameters: FVC, FEV1, FEV1%, PEF, FEF25–75, FET, Lung Age, VC, IVC. Oximetry (Optional): %SpO2 [Baseline, Min, Max, Mean], Pulse Rate [Baseline, Min, Max, Mean] Events. |
Data sheet
- Manufacturer reference
- 911021E2
- Type
- Portable