MIR Spirobank II Advanced Plus with 60 FlowMir turbines and oximetry

1528 € Reference: 516144

Spirobank II Advanced Plus spirometer is the most powerful and simple portable spirometer by MIR. The memory is up to 10.000 spirometer test & oximeter with 1000 hours recording. Stand alone or PC online operation (realtime using WinSpiroPRO high end software). Spirobank II Advanced Plus has graphic display with user friendly icons. Patient identification by name or ID code. Bluetooth® 2.1 connection to printer or mobile phone. USB, RS232 and wireless acoustic modem. Upgradeable internal software via internet.

Spirometry features FVC, VC, IVC, MVV, PRE-POST BD. It Automatically records the best 3 trials. Internal temperature sensor for automatic BTPS. Advanced spirometry test interpretation. Lung age estimation.

With the Spirobank II Advanced Plus module you can get sleep disorder detection with events recording. Six minute walk test with automatic alarm for rest, walk and recovery. Parameters directly shown on the display (min, max, mean SpO2 and Pulse Rate, Δ Index, T90, T89, T88, T5, ODI, NOD, Desaturation Area etc.). Its innovative functions make it the most unique oximeter on the market. It has a large display. All results are shown directly on the display and it comes with winspiroPRO PC software

The Spirobank II Advanced Plus features various Spirometry programs such as Flow/Volume and Volume/time curves, PRE-POST bronchodilator comparison, FEV1 dose-response curve, Exclusive pediatric incentive system, Advanced spirometry test interpretation, Several sets of predicted values, Integration with Electronic Medical Record and finally data and graphs export even via e-mail.

Spirobank II Advanced Plus spirometer inludes:

Depending on your needs the Spirobank II Advanced Plus spirometer  can measure:

FVC, FEV1, FEV1/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FET, Vext, FIVC, FIV1, FIV1/FIVC%, PIF, *FVC, *FEV1, *PEF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, MVV (* = Best value). 

Basic: SpO2 [Baseline, Min, Max, Mean], Pulse Rate [Baseline, Min, Max, Mean], T90 [SpO2<90%], T89 [SpO2<89%], T88 [SpO2<88%], T5 [ΔSpO2>5%], Δ Index [12s], SpO2 Events, Pulse Rate Events [Bradycardia, Tachycardia]

6 Minute Walk Test:TΔ2 [SpO2≥2%], TΔ4 [ΔSpO2≥4%], Recording time, Time [Rest, Walking, Recovery], Walked Distance, Predicted Distance [Min, Standard], Desaturation Area/Distance, Borg Dyspnea [Baseline, End, Change], Borg Fatigue [Baseline, End, Change]

Sleep Test: Desaturatin Events, Desaturation Index (ODI), Desaturation [Value, Duration, Nadir], ΔSpO2 [Min Drop, Max Drop], Pulse Variations, Pulse Rate Index, NOD 89 [SpO2<89%; >5 min], NOD 4 [SpO2 Baseline-4%; >5 min], NOD 90 [SpO2<90%; Nadir <86%; >5 min]

Available options:

The package includes:

Compatible turbines:

Mouthpiece Turbine
Disinfection
Turbine
Calibration
Packaging Antiviral
filter
FlowMIR
Disposable Turbine
Included
Disposable
Not
required
Not
required
60 pieces Available
Disposable
Reusable Turbine Required,
Not included
Required Required 1 unit  Required,
Disposable
Technical
Specification
Spirobank II
Basic
Spirobank II
Advanced
Spirobank II
Smart
Type of spirometer StandAlone + PC StandAlone + PC,
with Oximetry Option
StandAlone + PC + App,
with Oximetry Option
Compatible turbines flowMIR™ Disposable Turbine,
Reusable Turbine Flowmeter
flowMIR™ Disposable Turbine,
Reusable Turbine Flowmeter
flowMIR™ Disposable Turbine,
Reusable Turbine Flowmeter
Compatible softwares Winspiro PRO, spiro Connect MIR Spiro App, Winspiro PRO,
spiro Connect
External control Real-Time test on PC screen,
connect with your EHR/EMR,
back-up internal memory and much more

Connect to your PC via USB
Real-Time test on PC screen,
connect with your EHR/EMR,
back-up internal memory, and much more

Connect to your PC via USB and Bluetooth 2.0
Real-Time test on Tablet and PC screen,
connect with your EHR/EMR,
backup internal memory, and much more

Connect to your PC via USB (no Bluetooth)

Connect to your Tablet via Bluetooth Smart BLE 4.0
EHR connectivity Via PC, integration with patient database
on your EHR/EMR (in HL7, GDT)
Via PC, integration with patient database on
your EHR/EMR (in HL7, GDT)
Via PC: integration with patient database
on your EHR/EMR (in HL7, GDT)
Via APP: transfer data to a remote server
in HL7 standards
Measured parameters Spirometry: FVC, VC, IVC, PRE/POST
Bronchodilator comparison

Spirometry: FVC, VC, IVC, IC, ERV, FEV1,
FEV1%, PEF, FEF 25-75, FET, EVOL, ELA
Spirometry: FVC, VC, IVC, MVV, PRE-POST
Bronchodilator comparison
Oximetry (optional): Spot test (SpO2, BPM)

Spirometry: FVC, FEV1, FEV1/FVC%, DTPEF,
FEV 0.5, FEV0.5/FVC%, FEV0.75,
FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3,
FEV3/FVC%, FEV6, FEV1/FEV6%, PEF,
FEF25%, FEF50%, FEF75%, FEF25-75%,
FEF75-85%, FET, Vext, ELA, EVOL, FIVC, FIV1,
PIF, FIV1/FIVC%, FIF25%, FIF50%, FIF75%,
R50, PIF, IRV, VC, IVC, IC, ERV, FEV1/VC%,
TV, VE, RR, ti, te, ti/t-tot, TV/ti, MVV

Oximetry (Optional): SpO2% (min, max,
average), BPM (min, max, average), Test
duration, % Bradycardia Duration (<40
BPM), % Tachycardia Duration (>120 BPM),
% of Time with SpO2 ≤ 90% (T90%, T89%)
Spirometry: FVC, VC, IVC, MVV, PRE-POST
Bronchodilator comparison
Oximetry (optional): Spot test (SpO2, BPM)

Spirometry: FVC, FEV1, FEV1/FVC%, DTPEF,
FEV 0.5, FEV0.5/FVC%, FEV0.75,
FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3,
FEV3/FVC%, FEV6, FEV1/FEV6%, PEF,
FEF25, FEF50, FEF75, FEF25-75, FEF75-85%,
FET, Vext, ELA, EVOL, FIVC, FIV1, PIF,
FIV1/FIVC%, FIF25, FIF50, FIF75, R50, PIF,
IRV, VC, IVC, IC, ERV, FEV1/VC%, TV, VE, RR,
tI, tE, tI/t-tot, TV/tI, MVV

Oximetry (Optional): SpO2% (min, max,
average), BPM (min, max, average), Test
duration, % Bradycardia Duration (<40
BPM), % Tachycardia Duration (>120 BPM),
% of Time with SpO2 ≤ 90% (T90%, T89%)

on MIR Spiro App:
Spirometry: FVC, VC, PRE/POST
Bronchodilator comparison
Parameters: FVC, FEV1, FEV1%, PEF,
FEF25–75, FET, Lung Age, VC, IVC.
Oximetry (Optional): %SpO2 [Baseline, Min,
Max, Mean], Pulse Rate [Baseline, Min,
Max, Mean] Events.

Add to cart