MIR Spirobank II Advanced spirometer is a portable device for spirometry of the most basic parameters of respiratory function, thus providing a complete picture of the patient. The MIR Spirobank II Advanced spirometer is accurate, fast, and easy to operate, with an icon-based navigation menu and a high-resolution backlit display for flexible operation.
Also, the MIR Spirobank II Advanced spirometer immediately displays the results on the screen with a preview of the curves for data analysis, and average interpretation of the test. It works with a long-life rechargeable battery (40 hours of continuous operation). The Spirobank II Advanced spirometer has a built-in memory of 10.000 measurements. It is connected to a computer via USB or Bluetooth connection and the winspiroPRO software (included) and performs the examination in real-time. It measures the parameters FVC, VC, IVC, IC ERV, PRE and POST, FEV1, FEV1%, PEF, FEF 25- 75%, FET, EBOL. In addition, it has the ability to calculate a series of more than 40 parameters.
Measurement parameters: FVC, FEV1, FEV1/FVC%, DTPEF, FEV 0.5, FEV0.5/FVC%, FEV0.75, FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3, FEV3/FVC%, FEV6 , FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FEF75-85%, FET, Vext, ELA, EVOL, FIVC, FIV1, PIF, FIV1/FIVC%, FIF25%, FIF50 %, FIF75%, R50, PIF, IRV, VC, IVC, IC, ERV, FEV1/VC%, TV, VE, RR, ti, te, ti/t-tot, TV/ti, MVV
The package includes:
- MIR Spirobank II Advanced Spirometer
- Carrying case
- USB cable
- 1 nose clip
- PC Software
Specifications:
- Width: 55mm
- Length: 160mm
- Thickness: 25mm
- Weight: 140g (battery included)
- Connectivity: USB 2.0, Bluetooth® 2.1
- Display: LCD, 160 × 80 pixels
- Keyboard: membrane, with 6 keys
- Mouthpieces: Ø 30 mm (1.18 inches)
- Power supply: 3.7 V, 110 mA lithium battery (rechargeable via USB)
- Keyboard: 6-key membrane keyboard
- Autonomy: 50 hours
- Memory: 10.000 measurements
Compatible Turbines:
Mouthpiece | Turbine Disinfection |
Turbine Calibration |
Packaging | Antiviral filter |
|
---|---|---|---|---|---|
FlowMIR Disposable Turbine |
Included Disposable |
Not required |
Not required |
60 pieces | Available Disposable |
Reusable Turbine | Required, Not included |
Required | Required | 1 unit | Required, Disposable |
Technical Specification |
Spirobank II Basic |
Spirobank II Advanced |
Spirobank II Smart |
---|---|---|---|
Type of spirometer | StandAlone + PC | StandAlone + PC, with Oximetry Option |
StandAlone + PC + App, with Oximetry Option |
Compatible turbines | flowMIR™ Disposable Turbine, Reusable Turbine Flowmeter |
flowMIR™ Disposable Turbine, Reusable Turbine Flowmeter |
flowMIR™ Disposable Turbine, Reusable Turbine Flowmeter |
Compatible softwares | Winspiro PRO, spiro Connect | MIR Spiro App, Winspiro PRO, spiro Connect |
|
External control | Real-Time test on PC screen, connect with your EHR/EMR, back-up internal memory and much more Connect to your PC via USB |
Real-Time test on PC screen, connect with your EHR/EMR, back-up internal memory, and much more Connect to your PC via USB and Bluetooth 2.0 |
Real-Time test on Tablet and PC screen, connect with your EHR/EMR, backup internal memory, and much more Connect to your PC via USB (no Bluetooth) Connect to your Tablet via Bluetooth Smart BLE 4.0 |
EHR connectivity | Via PC, integration with patient database on your EHR/EMR (in HL7, GDT) |
Via PC, integration with patient database on your EHR/EMR (in HL7, GDT) |
Via PC: integration with patient database on your EHR/EMR (in HL7, GDT) Via APP: transfer data to a remote server in HL7 standards |
Measured parameters | Spirometry: FVC, VC, IVC, PRE/POST Bronchodilator comparison Spirometry: FVC, VC, IVC, IC, ERV, FEV1, FEV1%, PEF, FEF 25-75, FET, EVOL, ELA |
Spirometry: FVC, VC, IVC, MVV, PRE-POST Bronchodilator comparison Oximetry (optional): Spot test (SpO2, BPM) Spirometry: FVC, FEV1, FEV1/FVC%, DTPEF, FEV 0.5, FEV0.5/FVC%, FEV0.75, FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FEF75-85%, FET, Vext, ELA, EVOL, FIVC, FIV1, PIF, FIV1/FIVC%, FIF25%, FIF50%, FIF75%, R50, PIF, IRV, VC, IVC, IC, ERV, FEV1/VC%, TV, VE, RR, ti, te, ti/t-tot, TV/ti, MVV Oximetry (Optional): SpO2% (min, max, average), BPM (min, max, average), Test duration, % Bradycardia Duration (<40 BPM), % Tachycardia Duration (>120 BPM), % of Time with SpO2 ≤ 90% (T90%, T89%) |
Spirometry: FVC, VC, IVC, MVV, PRE-POST Bronchodilator comparison Oximetry (optional): Spot test (SpO2, BPM) Spirometry: FVC, FEV1, FEV1/FVC%, DTPEF, FEV 0.5, FEV0.5/FVC%, FEV0.75, FEV0.75/FVC%, FEV2, FEV2/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25, FEF50, FEF75, FEF25-75, FEF75-85%, FET, Vext, ELA, EVOL, FIVC, FIV1, PIF, FIV1/FIVC%, FIF25, FIF50, FIF75, R50, PIF, IRV, VC, IVC, IC, ERV, FEV1/VC%, TV, VE, RR, tI, tE, tI/t-tot, TV/tI, MVV Oximetry (Optional): SpO2% (min, max, average), BPM (min, max, average), Test duration, % Bradycardia Duration (<40 BPM), % Tachycardia Duration (>120 BPM), % of Time with SpO2 ≤ 90% (T90%, T89%) on MIR Spiro App: Spirometry: FVC, VC, PRE/POST Bronchodilator comparison Parameters: FVC, FEV1, FEV1%, PEF, FEF25–75, FET, Lung Age, VC, IVC. Oximetry (Optional): %SpO2 [Baseline, Min, Max, Mean], Pulse Rate [Baseline, Min, Max, Mean] Events. |
Data sheet
- Manufacturer reference
- 911020E0
- Type
- Portable